EuroProbe 3

EuroMedical

EuroProbe 3


Print
Enquire


With a single readout module and numerous gamma probe options, the Europrobe 3.2 is a unique system that fulfills all needs of per and post-operative detection as well as per-cutaneous localisation within 7 major clinical fields : Breast, gynaecology, ENT, dermatology, endocrinology, urology and nuclear medicine.

The characteristics of the detector, its shape, size and sensitivity maybe adapted to any appropriate isotopes needed to meet clinical requirements. Every probe can be suited with an optional collimator.
All our probes are manufactured in biocompatible medical stainless steel, and a sterile biocompatible cover has been specially developed to suit the whole range.

Furthermore, the Europrobe probes are compliant with the IP68, ISO10993-5, ISO10993-10, ISO10993-11 biocompatibility standards.

  • Preset energy windows for the most common isotopes (99mTc, 125I, 131I, 18F).
  • Customizable energy window.
  • Easy start-up and configuration.
  • No calibration required.
  • No time drift.
  • 9 recordable user configurations, plus one default configuration.

      Counting: 30 000 cps
      Operating temperature: + 15˚C to 40˚C
      Height: 245 mm
      Width / Depth: 233 mm / 270 mm
      Weight: 2 Kg
      Consumption: 15 watts maximum
      Power supply: 115/220 VAC F = 50Hz

      Europe: CE 0459 (G-Med : class 2a)
      USA FDA Registered n° 9032627
      File Number: 244973

      Code Descriptions
      EP 3.2 EuroProbe 3 Readout Module
      CdTe Probes (Energy: 20-364keV- Isotope: Tc-99m, I-125, I-111) Cut Ø/ Length
      (mm)
      Form /
      Playback
      SOE 3206 ROLL : Sensitivity > 50Cps/MBq - Not palpable not visible tumor location 6/187 Straight/
      Axial
      SOE 3211 SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air / Fwhm = 37mm 11/192 Curved/
      Axial
      SOE 3211-D SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air 11/194 Straight/
      Axial
      SOE 3211-AC SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - With additional integrated collimator 15/198 Curved/
      Axial
      SOE 3211-D-AC SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - With additional integrated collimator 15/199 Straight/
      Lateral
      SOE 3211-14 SLN – Sensitivity > 1500 Cps/MBq – Fwhm = 44mm 14/194 Curved/
      Axial
      SOE 3211-14-D SLN –Sensitivity > 1500 Cps/MBq – Fwhm = 44mm 14/199 Straight/
      Axial
      SOE 3211-14-AC SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm dans l’air - With additional integrated collimator 18/200 Curved/
      Axial
      SOE 3211-14-D-AC SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - With additional integrated collimator 18/201 Straight/
      Axial
      SOE 3211-AF SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - Laparoscopic frontal detection 10/429 Straight/
      Axial
      SOE 3211-AL SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - Laparoscopic lateral detection 10/429 Straight/
      Lateral
      SOE 3211-AL-45 SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - Laparoscopic lateral detection at 45° 10/432 Straight/
      Lateral
      SOE 3211-AF-BT SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - Laparoscopic frontal detection - Wireless 10/492 Straight/
      Axial
      SOE 3211-AL-BT SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - Laparoscopic lateral detection - Wireless 10/493 Straight/
      Lateral
      SOE 3211-AL-45-BT SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - Laparoscopic lateral detection at 45° - Wireless 10/495 Curved/
      Lateral
      CsI Probes  (Energy: 100keV-1MeV -  Isotope: Tc-99m, I-131, I-111, F-18)
      SOE 3216 SLN – Sensitivity > 800Cps/MBq for a source of 57Co at 30mm in the air - Fwhm = 43mm 16/199 Curved/
      Axial
      SOE 3216-AC SLN - With additional integrated collimator 19/205 Curved/
      Axial
      SOE 3216-D-AC SLN - With additional integrated collimator 19/207 Straight/
      Axial
      SOE 3216-7 SLN – Sensitivity > 1700 Cps/MBq - Fwhm = 58mm 16/199 Curved/
      Axial
      SOE 3216-7-D SLN – Sensitivity > 1700 Cps/MBq - Fwhm = 58mm 16/201 Straight/
      Axial
      SOE 3216-7-AC SLN - With additional integrated collimator 19/205 Curved/
      Axial
      SOE 3216-7-D-AC SLN - With additional integrated collimator 19/207 Straight/
      Axial
      SOE 3216-11 SLN – Sensitivity > 800Cps/MBq for a source of 57Co at 30mm in the air - Fwhm = 38mm 11/197 Curved/
      Axial
      SOE 3216-11-D SLN – Sensitivity > 800Cps/MBq for a source of 57Co at 30mm in the air – Fwhm = 38mm 11/199 Straight/
      Axial
      SOE 3216-11-AC SLN - With additional integrated collimator 15/203 Curved/
      Axial
      SOE 3216-11-D-AC SLN - With additional integrated collimator 15/205 Straight/
      Axial
      SOE 3216-AC- BT SLN - With additional integrated collimator - Wireless 15/266 Curved/
      Axial

       

      EuroProbe 3 Brochure

      EuroProbe 3 Manual

      EuroProbe 3 Quick Start Guide