With a single readout module and numerous gamma probe options, the Europrobe 3.2 is a unique system that fulfills all needs of per and post-operative detection as well as per-cutaneous localisation within 7 major clinical fields : Breast, gynaecology, ENT, dermatology, endocrinology, urology and nuclear medicine.
The characteristics of the detector, its shape, size and sensitivity maybe adapted to any appropriate isotopes needed to meet clinical requirements. Every probe can be suited with an optional collimator.
All our probes are manufactured in biocompatible medical stainless steel, and a sterile biocompatible cover has been specially developed to suit the whole range.
Furthermore, the Europrobe probes are compliant with the IP68, ISO10993-5, ISO10993-10, ISO10993-11 biocompatibility standards.
- Preset energy windows for the most common isotopes (99mTc, 125I, 131I, 18F).
- Customizable energy window.
- Easy start-up and configuration.
- No calibration required.
- No time drift.
- 9 recordable user configurations, plus one default configuration.
Counting: 30 000 cps
Operating temperature: + 15˚C to 40˚C
Height: 245 mm
Width / Depth: 233 mm / 270 mm
Weight: 2 Kg
Consumption: 15 watts maximum
Power supply: 115/220 VAC F = 50Hz
Europe: CE 0459 (G-Med : class 2a)
USA FDA Registered n° 9032627
File Number: 244973
Code | Descriptions | ||
EP 3.2 | EuroProbe 3 Readout Module | ||
CdTe Probes (Energy: 20-364keV- Isotope: Tc-99m, I-125, I-111) | Cut Ø/ Length (mm) |
Form / Playback |
|
SOE 3206 | ROLL : Sensitivity > 50Cps/MBq - Not palpable not visible tumor location | 6/187 | Straight/ Axial |
SOE 3211 | SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air / Fwhm = 37mm | 11/192 | Curved/ Axial |
SOE 3211-D | SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air | 11/194 | Straight/ Axial |
SOE 3211-AC | SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - With additional integrated collimator | 15/198 | Curved/ Axial |
SOE 3211-D-AC | SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - With additional integrated collimator | 15/199 | Straight/ Lateral |
SOE 3211-14 | SLN – Sensitivity > 1500 Cps/MBq – Fwhm = 44mm | 14/194 | Curved/ Axial |
SOE 3211-14-D | SLN –Sensitivity > 1500 Cps/MBq – Fwhm = 44mm | 14/199 | Straight/ Axial |
SOE 3211-14-AC | SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm dans l’air - With additional integrated collimator | 18/200 | Curved/ Axial |
SOE 3211-14-D-AC | SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - With additional integrated collimator | 18/201 | Straight/ Axial |
SOE 3211-AF | SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - Laparoscopic frontal detection | 10/429 | Straight/ Axial |
SOE 3211-AL | SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - Laparoscopic lateral detection | 10/429 | Straight/ Lateral |
SOE 3211-AL-45 | SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - Laparoscopic lateral detection at 45° | 10/432 | Straight/ Lateral |
SOE 3211-AF-BT | SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - Laparoscopic frontal detection - Wireless | 10/492 | Straight/ Axial |
SOE 3211-AL-BT | SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - Laparoscopic lateral detection - Wireless | 10/493 | Straight/ Lateral |
SOE 3211-AL-45-BT | SLN – Sensitivity > 300Cps/MBq for a source of 57Co at 30mm in the air - Laparoscopic lateral detection at 45° - Wireless | 10/495 | Curved/ Lateral |
CsI Probes (Energy: 100keV-1MeV - Isotope: Tc-99m, I-131, I-111, F-18) | |||
SOE 3216 | SLN – Sensitivity > 800Cps/MBq for a source of 57Co at 30mm in the air - Fwhm = 43mm | 16/199 | Curved/ Axial |
SOE 3216-AC | SLN - With additional integrated collimator | 19/205 | Curved/ Axial |
SOE 3216-D-AC | SLN - With additional integrated collimator | 19/207 | Straight/ Axial |
SOE 3216-7 | SLN – Sensitivity > 1700 Cps/MBq - Fwhm = 58mm | 16/199 | Curved/ Axial |
SOE 3216-7-D | SLN – Sensitivity > 1700 Cps/MBq - Fwhm = 58mm | 16/201 | Straight/ Axial |
SOE 3216-7-AC | SLN - With additional integrated collimator | 19/205 | Curved/ Axial |
SOE 3216-7-D-AC | SLN - With additional integrated collimator | 19/207 | Straight/ Axial |
SOE 3216-11 | SLN – Sensitivity > 800Cps/MBq for a source of 57Co at 30mm in the air - Fwhm = 38mm | 11/197 | Curved/ Axial |
SOE 3216-11-D | SLN – Sensitivity > 800Cps/MBq for a source of 57Co at 30mm in the air – Fwhm = 38mm | 11/199 | Straight/ Axial |
SOE 3216-11-AC | SLN - With additional integrated collimator | 15/203 | Curved/ Axial |
SOE 3216-11-D-AC | SLN - With additional integrated collimator | 15/205 | Straight/ Axial |
SOE 3216-AC- BT | SLN - With additional integrated collimator - Wireless | 15/266 | Curved/ Axial |